ladder/school/conveyor.st · 621 字节 · 下载原文
(* Conveyor POU — start/stop/e-stop control with motor output *)
FUNCTION_BLOCK Conveyor
VAR_INPUT
start_btn : BOOL;
stop_btn : BOOL;
estop : BOOL;
END_VAR
VAR_OUTPUT
motor_run : BOOL;
fault_lamp : BOOL;
END_VAR
VAR
running : BOOL;
END_VAR
(* Emergency stop overrides everything *)
IF estop THEN
running := FALSE;
fault_lamp := TRUE;
ELSIF start_btn AND NOT stop_btn THEN
running := TRUE;
fault_lamp := FALSE;
ELSIF stop_btn THEN
running := FALSE;
fault_lamp := FALSE;
ELSE
fault_lamp := FALSE;
END_IF
motor_run := running;
END_FUNCTION_BLOCK